in the year: 1999



Basic data
Station number: 1417
Station name: Medenec
Station type: stacionary - HM-aerosol
District: Chomutov
Institution: Czech Hydrometeorological Institute
Laboratory address
ANALYTIKA - TK
Ing. Koubek
U Elektry 650
198 00 Praha 9
Tel: 047/43255
Fax: 047/49245
Impeachable worker address
ČHMÚ-pobočka Ústí n/Labem
Mgr.Janatová L.
Pošt.přihrádka 2
400 11 Ústi nad Labem
Tel: 047/2773218
Fax: 047/2778896
Location
Geographics coordinates:latitude: 50° 25' 41" ;   longitude: 13° 7' 55"
Altitude: 827 m
Expletory data of station
Landscape: Upland platform area (peak, ridge) in terrain of declination up to 10%
Scenery: Agricultural land (Arable land predominates.)
Representative: Local (Regional) scale (ten to hundreds km)
Purpose: Evaluation of total level of concentrations background
Verbal description placing
Na samotě u rekreačního střediska (1 budova) v okolí pole, nízká zeleň, ve vrcholové partii, mírný svah. Odběr : denní, analýza kovů každý 5.den.
Registration
Date of establishment station: 04-03-1992 Date of termination station: 03-09-1996
Pollutant
Method
Unit
Interval
Begin date
End date
V (vanadium) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Cr (chromium) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Mn (manganese) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Fe (iron) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Ni (nickel) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
As (arsenic) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Se (selenium) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Cd (cadmium) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Sb (antimony) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996
Pb (lead) ICP-MS (inductively coupled plasma - mass spectrometry)ng/m^3 24 h/5 dint 05-01-199601-07-1996